Product Name: pressure transmitter - fl102-a high precision differential pressure transmitter - fl102-a high precision differential pressure transmitter
Product No.: 134724-786
Product model: fl102-a
Updated on: August 31, 2017
Production unit: [thermocouple] - Shanghai Feilong instrument and Electrical Co., Ltd. 021-63801621
Product details
Fl102-a high precision differential pressure transmitter
Fl103-a high precision differential pressure transmitter
Fl102 / 3-A high dry degree differential pressure / absolute pressure transmitter is used to measure the liquid level, density and pressure of liquid, gas or steam, and then convert it into 4 ~ 20mADC Hart current signal output. Fl102 / 3-A can also communicate with rst375 handheld terminal or rsmioomodem for parameter setting, process monitoring, etc.
Standard specification: (adjust * range based on standard zero point, stainless steel 316L diaphragm, filling liquid is silicone oil)
1. Performance specifications
Reference accuracy of adjustment range (including linearity, backlash and internal repeatability from zero point)}: ± 0.05%
If td > 10 {td = maximum m-pass / adjustment set-up >, it is: ± (0 xtd)%
Impact of ambient temperature
-The total effect at 20 ℃ - 65 ℃ is: ± (0.075 * TD + 0.025)% x span
± 0.04% per 10 ℃ (td = 1}
The total influence amount at - 40 ℃ ~ - 20 ℃ and 65 ℃ - 85 ℃ is ± (0_1x TD + 0.025 >% x span
Over range impact: ± 0.05% x span
Stability: ± 0.1% * span / 3 years
Power effect: ± (0.001% / 10V {12-42v DC >, negligible
2. Functional specifications
Limit of path
Within the upper and lower limits of m-pass, it can be adjusted arbitrarily. It is recommended to select m program code with the lowest m program ratio as possible to optimize performance characteristics.
Setting range and range (fi102-a high precision gauge pressure >
Range and range (fl103-a high precision absolute pressure)
Zero point setting: zero point and M range can be adjusted to any value within the range of M measured in the table, as long as the calibration is the minimum range
Influence of installation position: the change of installation position s parallel to and reverse to the one-sided will not cause zero drift effect. If the change of installation position s and membrane one-sided exceeds 90 °, there is a zero effect within the range of < 0.25kpa in m-pass C, and < 0.15kpa in other m-passes
The influence of internal zero position can be corrected by adjusting the extraction. There is no impact of M process.
Output: 2-wire system, 4-20madc Hart output, digital communication, linear or square root output can be selected, HART protocol is added to 4-20madc signal.
Output signal limit: 1min = 3.9ma, Lmax = 20.5ma
Bitter current: low alarm mode (minimum): 3.7 Ma
High alarm mode (maximum): 21 Ma
Non alarm mode (hold): keep the effective current value before the fault. The current standard is set as s: high alarm mode
Response time: the damping constant of amplifier component is 0.1s; the sensor time constant is 0.1 ~ 1.6s, which depends on * path and * path ratio. The additional adjustable time constant is 0.1-60s.
Preheating time: < 15s
Ambient temperature: - 40-85c
- 20-651 with liquid crystal display and fluororubber sealing ring
Storage temperature / transportation temperature: - 50-851
With LCD: - Ao SST
Pressure limit: from vacuum to maximum range
Overload limit:
Explosion proof performance
Neps license: Exd iict6
Nepsi intrinsic safety license: Exia iict4
The allowable operating temperature is: - 40 ^ ^ 651
3, installation
Power supply and load conditions: power supply voltage is 24V, r = 1C (us-12v > / lmaxkq, where Lmax = 23ma, maximum power supply voltage: 42vdc
Minimum power supply voltage: 12VDC, 15Vdc (backlit LCD display) digital communication load range: 230 ~ 600q
Electrical connection: m20x 1.5 cable sealing buckle, terminal is suitable for 0.5-2 μ 5mm2 conductor.
Process connection: standard process connection: NPT 1 / 2 internal butterfly, can be converted into npt1 / 2, G1 / 2 and m20x1.5 external butterfly, kf16 vacuum interface
4. Physical specifications
Texture of material
Patellar: stainless steel 316L, Hastelloy C
Process connection: stainless steel 316
Filling liquid: silicone oil, fluorine oil
Transmitter shell: aluminum alloy, outer surface spray ring, air resin
Housing sealing ring: NBR >
Nameplate: stainless steel 304
Weight M: 1.6kg (No: LCD, mounting bracket, process connection)
External protection class: IP67
Electromagnetic compatibility (EMC}
See the following table "electromagnetic compatibility schedule"
EMC schedule
Note: (1) a performance level description: during the test, the performance is normal within the limit of technical specifications.
(2) B performance level description: during the test, the function or performance is temporarily reduced or lost, but it can be recovered by itself, and the actual operating condition, storage and data are not changed.