Product站內搜索聯系我們ADD: No. 1260 Lane 21 Sanzao Road, Pudong New Area, Shanghai, China HP: 13918773239 LINKMAN: Manager Shi EMAIL: sales03@sh9t.com |
ZK Series Thyristor Voltage RegulatorNumber of products: 195034-559 Product model: 0 Updated: 2009.06.13 Manufacturer: Thermocouple--Shanghai Feilong Instrument Electric Co., Ltd. Product details ZK Series Thyristor Voltage Regulator I. scope of application ZK series controllable voltage regulator XCT- 1 9 x 1/2, XFT- 1 9 x 1/2, TA-09 x 1/2, TE-090 x 1/2, XTM-290x1 / 2, FESA-890x1 / 2 instruments and ≤ KP-200A (three-phase 600A) thyristor components can be used as single-phase or three-phase voltage and power adjustment, so that the furnace temperature of the resistance furnace (or induction heating furnace) can be automatically control. It has high adjustment accuracy and strong anti-interference ability. In order to meet the technical development and market needs, it is convenient for users to have improved products in this series. The improved zk series instruments use integrated circuits to increase the amplitude, width, and conduction angle of the instrument's trigger pulses, improving the reliability of the instrument and making it more widely applicable. ZK—1 single-phase phase-shift trigger ZK-03 three-phase zero-crossing trigger (high-power resistance furnace) Note: ZK-19pZK-50ZK-100ZZ200ZK-03 is a three-phase half-control and its improved type is half-control or full-control. Third, the main technical indicators 1. Shell type: instrument panel type. 2. Input signal: O-1mA DC. 3. Output signal (phase-shift trigger pulse): ZK-1 type: amplitude is not less than 50mA, width is greater than 25uS. ZK-100, ZK-200 type: amplitude is not less than 200mA, width is more than 35uS. 4. Phase shifting angle: not less than 150 ′ for each half-cycle of AC. 5. Working environment: temperature 0-50 ℃, relative humidity not exceeding 85%. 6. Power supply: AC 220V 110%, 50 weeks. 7. Power consumption: less than 4 volt-amps. 8, with SCR specifications: ZK-1 type: 3CT-20A / 500V. Or 3CT-50A / 500V. 3CT—100A / 600V. 3CT—200A / 600V. 9. Dimensions: 160x80x272 (mm). Input O-10mA DC 4-20mA DC P value adjustable range 0-100% Input impedance 800Q (O-10mA DC) 2500Q (4-20mA DC) Power 5W (ZK— ”8W (ZK-03) General guide, 150 degrees (ZK-1 AC half cycle) Weight 3Kg (ZK-1) 3.8-4. 5Kg (ZK-03) Output Pulse amplitude> 3V (Raise—1)> 4V (ZK-03) Width> 30us (ZK-1)> 400us (ZK-03) Working environment The temperature is O-50 ℃, the relative humidity does not exceed 85%, none Vibration, no corrosive gas. Switching cycle is now 3, 40 seconds, 512 seconds (ZK—03), 3—10 seconds, adjustable power supply 220V ± 10% 50HZ
|
|